Industrial Noise Control

Acoustic Enclosures

Walk-in acoustic rooms, modular enclosure boxes, and noise test rooms — engineered for industrial machinery, production line integration, and acoustic measurement applications.

Product Matrix

Compare enclosure routes by equipment, airflow, and access

Choose by the equipment type first, then compare the noise target, ventilation path, maintenance access, and quote inputs needed for a practical design review.

9

Routes

4

Core cues

Walk-in soundproof chamber for industrial equipment noise isolation
Walk-in room

Soundproof Chamber

Walk-in acoustic room for HVAC, generator, compressor, and industrial machinery noise control. Dimensions, access, and acoustic targets are reviewed by project.

Best fit
Equipment rooms
Noise target
Project-specific
Airflow
Intake / exhaust review
Access
Personnel or service doors

Quote inputs

Equipment type, room dimensions, airflow needs, access openings, site photos.

View Product
Air compressor acoustic enclosure with service access and ventilation planning
Compressor housing

Air Compressor Acoustic Enclosure

Custom enclosure for reciprocating and screw air compressors where cooling airflow, maintenance access, and site noise targets must be balanced.

Best fit
Screw / piston compressors
Noise target
After site review
Airflow
Cooling path first
Access
Filter, oil, belt service

Quote inputs

Compressor model, heat or airflow data, service side, pipe and cable routes.

View Product
Generator soundproof enclosure with acoustic ventilation and service doors
Power equipment

Generator Soundproof Enclosure

Soundproof generator enclosure for diesel and gas generator projects. Layout depends on generator size, airflow, service doors, and indoor or outdoor use.

Best fit
Diesel / gas gensets
Noise target
Project-specific
Airflow
Radiator path review
Access
Service sides and exhaust

Quote inputs

Generator model, radiator direction, exhaust route, service sides, installation space.

View Product
Fan and blower acoustic enclosure around industrial ventilation equipment
Airflow-sensitive

Fan & Blower Acoustic Enclosure

Acoustic hood and enclosure for industrial fans, blowers, and centrifugal units. Designed for airflow continuity with lined intake and discharge plenums.

Best fit
Fans and blowers
Noise target
After fan review
Airflow
Pressure drop checked
Access
Motor and inspection doors

Quote inputs

Fan type, airflow, duct size, pressure margin, motor position, access needs.

View Product
Industrial acoustic enclosure for machinery and production line noise control
Machinery enclosure

Industrial Acoustic Enclosure

Custom acoustic enclosures for factory machinery, CNC machines, metal presses, production lines, pumps, fans, and equipment rooms with site-specific constraints.

Best fit
Factory machinery
Noise target
Confirmed before quote
Airflow
Louver / silencer options
Access
Doors, windows, panels

Quote inputs

Machine footprint, access sides, heat or airflow data, target receiver location.

View Product
Pump room acoustic enclosure for pump and pipework noise control
Pump rooms

Pump Room Acoustic Enclosure

Acoustic planning for pump rooms, booster stations, hydraulic power units, and equipment rooms where airborne noise, vibration, pipe routing, and service access interact.

Best fit
Pump rooms / skids
Noise target
After room review
Airflow
Room or local treatment
Access
Valves and pump service

Quote inputs

Pump type, room drawings, pipe routing, wet conditions, receiver location.

View Product
HVAC acoustic enclosure for chiller and rooftop plant noise control
HVAC plant

HVAC Acoustic Enclosure

Purpose-designed acoustic enclosure route for AHUs, chillers, cooling towers, condensing units, and plant equipment where heat rejection must be preserved.

Best fit
Chillers / AHUs
Noise target
Modelled by project
Airflow
Heat rejection protected
Access
Full maintenance faces

Quote inputs

HVAC equipment model, airflow requirement, rooftop or plant-room layout, service zones.

View Product
Acoustic test room for product noise measurement and quality control
Testing space

Acoustic Test Room

Dedicated acoustic test room for end-of-line production noise checks, R&D acoustic measurement, and repeatable product testing environments.

Best fit
EOL / R&D testing
Noise target
Low-background room
Airflow
Silenced ventilation
Access
Fixture or conveyor route

Quote inputs

Product size, test standard, background noise target, automation or fixture needs.

View Product
Compact noise test enclosure for production line acoustic screening
Compact QC box

Noise Test Enclosure

Modular enclosure box for production-line acoustic screening, incoming QC, and product functional testing where a full test room is unnecessary.

Best fit
Compact equipment
Noise target
Screening enclosure
Airflow
Natural or forced vent
Access
Hinged / removable panels

Quote inputs

Machine size, cycle time, heat load, cable or hose openings, operator access.

View Product

Industrial noise problem to solve?

Send the equipment type, layout, airflow constraints, and target noise level for a project review.

Request Specifications